They have to pay attention to the two sounds of clunk found from the water heaters gas valve. Finally, install the thermostat professionally if it doesnt fit against the tank snugly. No spam, we promise. Fixing the error codes immediately is a must in the Pentair pool heater to avoid further problems to happen. Leak Shield shut off valve automatically shuts off watersupply when a leak is detected (accessoryincluded). We will also tell you the solutions that will help you to fix the problem. A flashing status light doesnt seem scary all the time. Repair or replace the sensor properly if there are any issues.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[120,600],'fireplacehubs_com-leader-4','ezslot_11',113,'0','0'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-leader-4-0');if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[120,600],'fireplacehubs_com-leader-4','ezslot_12',113,'0','1'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-leader-4-0_1');.leader-4-multi-113{border:none!important;display:block!important;float:none!important;line-height:0;margin-bottom:15px!important;margin-left:auto!important;margin-right:auto!important;margin-top:15px!important;max-width:100%!important;min-height:600px;padding:0;text-align:center!important}. Home | Sitemap | Blog| Privacy | Disclaimer | Contact| About. In other words, the thermopile itself gets defective or the wire connectors come loose. The water heater is surely essential to support modern households, and we can make sure that people will look for the best water heater which can be used for their household needs. Solution: Check for connection/breakage of wires, corrosion or frozen connectors, fan motor covered with dust, burn marks on the computer board. Generally, the water heater will display this faulty code if the outlet thermistor (TH-4) remains open. Necessary cookies are absolutely essential for the website to function properly. A.O. SMITH GAS WATER HEATER USER MANUAL Pdf Download On the other hand, your AO Smith Water Heater goes through problems if the status light flashes more than 1 times followed by a three-second pause. Too High Temperature 2. And this tutorial will help in replacing the thermocouple on the AO Smith Water Heater: Secondly, inspect the wire connectors for loose. As a second-generation plumber, it was easy for Anthony to get used to the technicalities of all from a tender age, Table Shower Ultimate Guide (Must Know Secrets), 3 Ways to REMOVE PVC Pipe From a FITTING (Video Review), How To Fix A Toilet Backing Up Into A Bath/Shower, Why Your Toilet Keeps Clogging And How To Fix It. FIX: Check is there a loose or breakage in wire connection or debris on the thermistor. Whats the average air temperature in the room where your water heater will be installed? More error codes can be found after all. Once you find the water is flowing uninterruptedly, turn off the hot water faucet and turn the power back to the unit. Now, relight the pilot light by following the step-by-step guide I mentioned earlier in this article. All rights reserved. It may take 90 seconds of pilot operation before the thermopile comes to its normal operating temp. So, continue reading to know how to fix the Pentair E05 heater error. What does E05 mean on a Pentair pool heater? Model HPX-66-DHPT120. Take the sensor out and make sure that all the wires are properly connected. Then, leave the unit for 10 minutes to let the thermopile cool down. View more. However, sometimes the provided manuals and instruction guides are not very clear and if you need help addressing some error codes that are popping up on your AO Smiths tankless water heater, then we have got you covered. ST. Manual for 300 models. ECS40200 FPCR50260E GCNH30100 GCNH50100 GCV30 GCV40. 01 Pressure Switch Fail On, should be Off 11 Pressure Switch Fail Off, should be On 02 Ignition Fail after 3 attempts 04 ECO Open 05 Temperature Probe Open 15 Temperature Out of Bounds < 30 degrees 25 Temperature Out of Bounds > 220 degrees The following Error Codes are internal to the controller. To fix this issue, you should replace the control board. It is a 50 gallon A O Smith just installed in new home 6 months ago.LG12-50R55DV 210. Before doing so, dont forget to check the wiring attached to the control board. var intYear = dteNow.getFullYear(); The owner is not there much in the spring and fall, like now, but the water heater is left running. Look for the blockage in the vent system and ensure if the distance between the intake and exhaust is not too small. This error code signifies that there is a problem with your outlet thermistor. 113 Flame On Should be Off Fail Manual for 400 - 1000 models. I checked all the wires and didn't find any problems, frayed insulation, etc. Smith Signature 100 40-Gallon Tall 9-year Limited 40000-BTU Natural Gas Water Heater Model # G9-T4040NVR Find My Store for pricing and availability 614 Style: Tall Family Size: 3-4 People Warranty: 9-year limited A.O. Products. } Error Code: 441, Light Blinks 2x What It's Telling You There is an issue with the flow sensor. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Firstly, the thermopile is at fault. The Solution Connections: Make sure the wiring is connected properly and isn't damaged. But then sometime later it will start to heat the water and the green light will begin flashing rapidly. If your AO Smith Water Heater status light flashes 1 time every 3 seconds, it indicates your water heater runs at its best condition. These are The Easy Steps, The sound of the door squeaking is certainly very, You may want to remove broken drills from wood when, Spray paint is an aerosol paint that is used by, The toilet flange heightis important for proper, After you receive your new washing machine, you are, Most people take it for granted that their, Like most people, you probably take your air, Copyright 2022 Burnshomeconstruction.com. As long as you see this error code, you must turn off the water heater first. Just shut off the electric supply to the unit. Take out the thermal regulator and replace it with a new one. Empty all the water that has accumulated in the exchanger properly. Continue with Recommended Cookies. This thermistor should be found attached to your water heaters exhaust. FIX: Check if the remote controller is the right type, also connections between the water heater and remote. Visually inspect the thermistor connections. Pentair Heater E05 Error Code [Reasons + Solutions] - FireplaceHubs Solution: Debris on the thermistor, loose or broken wire connection. Many reasons cause your water heater to heat the water excessively. Related Repair Pages:A.O. Water Heaters - A.O. This is the final error code for thermistor failure. 26C or 65C). According to the instruction, they also have to make the distance between the intake terminals and the exhaust terminal. Solution: See the error codes 331, 321, and 311. Put everything back into its place and turn the electricity on. Explore symptoms, causes, and a step-by-step repair guide for an easy repair. Next, thread a 4 section of gas pipe into the inlet and use it to turn the gas control valve counter-clockwise to remove the gas control valve. Error Code 51, 55, 510, 551, Six times Problem: Abnormal gas solenoid valve. They should also remove the grease or dirt which can be found in the fan motor as well as the gas burner. An AO Smith water heater's operating temperature range is 80F or 150F (approx. FREE Estimates! Our comprehensive A.O. event : evt, 6 Common Tankless Water Heater Problems And Solutions Below, I will explain the meaning of status light codes and what steps you should take to stop the blinking light. If there is a scale build up, then you should also check for any water leakages that are causing scale to build up inside your water heater. Higher temperatures increase the risk of scalding, but even at 120F, hot water can CODE: 11 (111), Three timesPROBLEM: The ignition failure. Ignition failure is not an uncommon issue with water heaters and boilers, but its also highly recommended that you solve this issue by calling a technician to your home. Solution: Check if the Hi-limit switch properly functions and that there is no loose or broken wire connections, no soot on the flame rod, or a damaged computer board. Related Price Pages:A.O. Is the surrounding air contaminated? They have to be very careful whether there is spark ignition buzzing from the burner. Turn on the electric supply by flipping up the circuit breaker. Turn the gas supply off at the manual shut-off valve on the gas supply line. If you want to increase the water heater thermostat(s) setting(s), How long does an A.O. Smith Signature 100 50-Gallons Tall 6-year Limited 40000-BTU Natural Gas Water Heater Model # G6N-T5040NVR The LED status light flashes 0 times or it doesnt come on due to two reasons. Look for the blockage in the vent system and ensure if the distance between the intake and exhaust is not too small. Sometimes if you are lucky, it could just be a bit of soot blocking the sensors other times, you may need to find a replacement AFR rod as soon as possible. I would Is there leaking from the heat exchanger? A.o. You dont need to take any corrective actions as the status light of a functioning unit blinks 1 time every 3 seconds. Electronic User Interface allows you to easily set temperature, operating mode, and child safety lock feature. FIX: Check is the Hi-limit switch properly functioning that there is no loose or broken wire connections, no soot on the flame rod or damaged computer board. When it senses the water temperature crosses the safety level, the reset or ECO button cuts the electric supply off. However, we often suggest professional help if the issue is complex. The leak of carbon monoxide is one of the carbon monoxide poisoning causes. They should be able to tell you the correct dipswitch settings for your model so you can correct it yourself. A Appliance Helpers representative is available for you 7 days-a-week including Holidays!! The initial setting is 120F, but you're in control after installation. If your AO Smith Electric Tankless Water Heater throws the error code E51 or E52, understand the user interface lost its connection with the control board. Also, you should check the computer board for any sign of burn marks too. Open a nearby hot water faucet to let the air out. I initially had to replace the lower element due to limescale. Smith Signature 100 50-Gallon Tall 6-year Limited 40000-BTU Natural Gas Water Heater Model # G6N-UT5040NVR Find My Store Your AO Smith Water Heater's status light will blink 5 times every three seconds if the temperature sensor gets defective. The average US household uses 64.3 gallons of hot water each day. Find the right water treatment products for your needs. Why is my AO Smith water heater not lighting? FIX: Check for the proper settings on the computer board. While it may be igniting, its not keeping its flame and is going out before it can adequately warm up your water. Low water flow and loose wiring also contribute to the Pentair Mastertemp e05 code. The solution for this problem is by checking the Hi-limit switch. This debris will be what is preventing your water heater from functioning properly. Replace everything back into its place. 12-Year limited residential warranty gives you peace of mind. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Now, turn on the drain valve to let the water drain. Takagi Water Heater Error Codes [Ultimate Guide], AO Smith Electric Water Heater Troubleshooting, AO Smith Water Heater Troubleshooting Codes, AO Smith Gas Water Heater Troubleshooting, 9 AO Smith Gas Water Heater Troubleshooting Tips, AO Smith Water Heater Not Heating [5 Easy Solutions], Bosch Tankless Water Heater Maintenance [The Complete Guide], Bosch Tankless Water Heater Troubleshooting [A Complete Guide], Bosch Tankless Water Heater Error Codes [Ultimate Guide].